<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-08 07-26-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 39 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 13 kHz 18034 0,1497
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,8 dBr -0,33 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 7:26, 8.07.2025
RT
"Ranni Plus - Prezident Donald Trump tvrdi, ze Teheran ma zaje..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 13 kHz MIN: 6 kHz % above 77 kHz: 0,1497 Acquired: 2025/07/08 7:26:55 Total samples: 18034 Equivalent time: 0:15:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,1 dBr MIN: -0,8 dBr AVE: -0,33 dBr % above 0,2 dBr: 0,0 Last value: -0,5 dBr (2025/07/08 7:26:54) 07:14 07:16 07:18 07:20 07:22 07:24 07:26 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality